Mixing time is specified per drum capacity. The unit prescribes a minimum mixing time of 1 minute for mixers up to which capacity?
Answer & Solution
Correct answer: A.
1. Mixing time governs how thoroughly the ingredients are blended in a batch.
2. The unit specifies 1 minute as the minimum mixing time for mixers up to 0.75 m³ capacity.
3. For every additional 0.75 m³ or fraction thereof, mixing time is increased by 0.25 minute.
4. Some mixers use a timer that prevents discharge until the prescribed time has elapsed.
5. The smaller capacity figures are not the threshold given by the unit.
_Source: IGNOU Concrete Technology, Unit 7 "Concreting Equipment" (Mixers, Cableways, Batchers, Buckets, Pre/Post Cooling)._
Related questions
Refrigeration plant capacity for pre-cooling of mass concrete is expressed in tons of refrIn the heat-balance equation, the specific heat of cement is generally taken between:In the heat-balance equation Eq. 7.2 for ice quantity, the latent heat of fusion of ice isIn the post-cooling pumping plant, each pipe coil is supplied at a flow rate of approximatThe unit specifies that individual embedded pipe runs may range from 180 to 360 m, with a Embedded post-cooling pipes carry circulating cool water through hardened concrete. The unCement is normally batched dry. To avoid moisture condensation that would adversely affectVacuum cooling of aggregates uses the lower boiling point of water at sub-atmospheric pres