In the post-cooling pumping plant, each pipe coil is supplied at a flow rate of approximately:
A1 to 2 litres per minute
B15 to 17 litres per minute
C5 to 7 litres per minute
D50 to 70 litres per minute
Answer & Solution
Correct answer: B. 15 to 17 litres per minute
1. The chosen flow rate must keep water flow turbulent inside the embedded pipe.
2. Turbulent flow drives the heat-transfer coefficient up, accelerating cooling.
3. The unit prescribes 15 to 17 litres per minute per coil.
4. This rate produces a velocity about four times the minimum turbulent threshold.
5. The lower and higher flow rates would either be laminar or wasteful.
_Source: IGNOU Concrete Technology, Unit 7 "Concreting Equipment" (Mixers, Cableways, Batchers, Buckets, Pre/Post Cooling)._
Keep practising Concreting Equipment
Browse all Concreting Equipment questions for B.Tech Civil, or explore more Civil Engineering topics.
Related questions
Refrigeration plant capacity for pre-cooling of mass concrete is expressed in tons of refrIn the heat-balance equation, the specific heat of cement is generally taken between:In the heat-balance equation Eq. 7.2 for ice quantity, the latent heat of fusion of ice isThe unit specifies that individual embedded pipe runs may range from 180 to 360 m, with a Liquid nitrogen is used as an alternate cooling agent. The unit gives its boiling temperatEnergy imparted to a batch during mixing converts to heat in the concrete. The unit estimaFor cycle-time calculations the unit lists suggested cableway speeds. The carriage travel In a radial-travelling cableway, two backstays are required at the stationary tower whenev