In the post-cooling pumping plant, each pipe coil is supplied at a flow rate of approximately:
Answer & Solution
Correct answer: B.
1. The chosen flow rate must keep water flow turbulent inside the embedded pipe.
2. Turbulent flow drives the heat-transfer coefficient up, accelerating cooling.
3. The unit prescribes 15 to 17 litres per minute per coil.
4. This rate produces a velocity about four times the minimum turbulent threshold.
5. The lower and higher flow rates would either be laminar or wasteful.
_Source: IGNOU Concrete Technology, Unit 7 "Concreting Equipment" (Mixers, Cableways, Batchers, Buckets, Pre/Post Cooling)._
Related questions
Refrigeration plant capacity for pre-cooling of mass concrete is expressed in tons of refrIn the heat-balance equation, the specific heat of cement is generally taken between:In the heat-balance equation Eq. 7.2 for ice quantity, the latent heat of fusion of ice isThe unit specifies that individual embedded pipe runs may range from 180 to 360 m, with a Embedded post-cooling pipes carry circulating cool water through hardened concrete. The unCement is normally batched dry. To avoid moisture condensation that would adversely affectVacuum cooling of aggregates uses the lower boiling point of water at sub-atmospheric presCoarse aggregate is cooled by inundation in a tank of chilled water. With water at 2 °C, e