Embedded post-cooling pipes carry circulating cool water through hardened concrete. The unit specifies pipe outer diameter and wall thickness as:
Answer & Solution
Correct answer: D.
1. Embedded cooling coils are thin-wall tubing chosen for heat transfer and ease of installation.
2. The unit specifies 25 mm nominal outer diameter and 1.5 mm wall thickness for both materials.
3. Aluminium tubing is light and easy to install but corrodes under cement chemistry.
4. For estimated active cooling periods exceeding 3 months, steel tubes should be used instead.
5. The other dimension pairs do not match the specified embedded-pipe geometry.
_Source: IGNOU Concrete Technology, Unit 7 "Concreting Equipment" (Mixers, Cableways, Batchers, Buckets, Pre/Post Cooling)._
Related questions
Refrigeration plant capacity for pre-cooling of mass concrete is expressed in tons of refrIn the heat-balance equation, the specific heat of cement is generally taken between:In the heat-balance equation Eq. 7.2 for ice quantity, the latent heat of fusion of ice isIn the post-cooling pumping plant, each pipe coil is supplied at a flow rate of approximatThe unit specifies that individual embedded pipe runs may range from 180 to 360 m, with a Cement is normally batched dry. To avoid moisture condensation that would adversely affectVacuum cooling of aggregates uses the lower boiling point of water at sub-atmospheric presCoarse aggregate is cooled by inundation in a tank of chilled water. With water at 2 °C, e