Coarse aggregate is cooled by inundation in a tank of chilled water. With water at 2 °C, even 15 cm top-size aggregate can be cooled to about 3 °C in a circulating time of approximately:
Answer & Solution
Correct answer: A.
1. The inundation tank is open-topped with a conical bottom and a watertight discharge gate.
2. Chilled water at 2 °C is circulated through the aggregate held in the tank.
3. The unit reports that 15 cm top-size aggregate is cooled to about 3 °C with a circulating time of 45 minutes.
4. The full filling and discharging cycle takes about 2 hours per batch.
5. The other times misstate the circulating time given by the unit.
_Source: IGNOU Concrete Technology, Unit 7 "Concreting Equipment" (Mixers, Cableways, Batchers, Buckets, Pre/Post Cooling)._
Related questions
Refrigeration plant capacity for pre-cooling of mass concrete is expressed in tons of refrIn the heat-balance equation, the specific heat of cement is generally taken between:In the heat-balance equation Eq. 7.2 for ice quantity, the latent heat of fusion of ice isIn the post-cooling pumping plant, each pipe coil is supplied at a flow rate of approximatThe unit specifies that individual embedded pipe runs may range from 180 to 360 m, with a Embedded post-cooling pipes carry circulating cool water through hardened concrete. The unCement is normally batched dry. To avoid moisture condensation that would adversely affectVacuum cooling of aggregates uses the lower boiling point of water at sub-atmospheric pres