Per Table 10.5 (durability in mix design), the MINIMUM cement content for REINFORCED concrete in 'severe' exposure is:
A{'text': '220 kg/m³ at w/c ≤ 0.7', 'label': 'A'}
B{'text': '250 kg/m³ at w/c ≤ 0.65', 'label': 'B'}
C{'text': '290 kg/m³ at w/c ≤ 0.55', 'label': 'C'}
D{'text': '360 kg/m³ at w/c ≤ 0.45', 'label': 'D'}
Answer & Solution
Correct answer: D. {'text': '360 kg/m³ at w/c ≤ 0.45', 'label': 'D'}
1. Table 10.5: Reinforced concrete cement minima and max w/c — Mild: 250 kg/m³, 0.65; Moderate: 290, 0.55; Severe: 360 kg/m³, w/c ≤ 0.45.
2. The same severity row caps plain concrete at 310 kg/m³ at w/c ≤ 0.5.
_Source: IGNOU ET-522 Block-3 Unit-10 Concrete Mix Design, Table 10.5, §10.8 Step 2, p. 17_
Related questions
Per §10.8 (Step 8), the correction applied to mix proportions when site aggregates are fouPer §10.10 (High Strength Concrete Mix), the addition of Condensed Silica Fume (CSF) at abPer §10.10 (High Strength Concrete Mix), the use of a SUPERPLASTICIZER allows the water coPer the worked illustrative example in §10.9 (M 20, 20 mm angular, 0.90 CF, good control, Per §10.8 (Step 9, Trial Mix), the calculated mix proportions are verified by casting at lPer §10.8 (Step 5, Table 10.9), the correction for using ROUNDED aggregate (instead of thePer §10.8 (Step 5, Table 10.9), if the actual compacting factor is 0.1 HIGHER than the refPer §10.8 (Step 5, Table 10.9), the correction to sand percentage when the available fine