Practice free →
HomeGATE MEMechanical Engineeringfibers › A BASIC requirement for a matrix material in FRP…

A BASIC requirement for a matrix material in FRP is:

A{'text': 'Lower elastic modulus than fibers', 'label': 'C'}
B{'text': 'STRAIN AT BREAK must be LARGER than the strain at break of the fibers it holds', 'label': 'B'}
C{'text': 'Higher density', 'label': 'D'}
D{'text': 'Higher tensile strength than the fibers', 'label': 'A'}
Answer & Solution
Correct answer: B. {'text': 'STRAIN AT BREAK must be LARGER than the strain at break of the fibers it holds', 'label': 'B'}
If the matrix were to fail at lower strain than fibers, the composite would fail at matrix failure — fibers never reach their capacity. Matrix strain-at-break > fiber strain-at-break ensures fibers carry load until their own failure.
Solve this in the app — GATE ME practice & 24k+ MCQs →