Per Table 1.5, the maximum permitted FINAL setting time of Ordinary Portland Cement is:
A{'text': '600 minutes', 'label': 'A'}
B{'text': '180 minutes', 'label': 'B'}
C{'text': '60 minutes', 'label': 'C'}
D{'text': '1440 minutes', 'label': 'D'}
Answer & Solution
Correct answer: A. {'text': '600 minutes', 'label': 'A'}
1. Table 1.5 lists the maximum final setting time as 600 minutes for OPC (33, 43, 53 Grade), low heat, rapid hardening, Portland Pozzolana, Portland Slag, hydrophobic Portland and super sulphated cements.
2. The minimum initial setting time is 30 minutes (60 minutes for low heat and hydrophobic).
_Source: IGNOU ET-522 Block-1 Unit-1 Cement, Table 1.5, §1.9, p. 13_
Related questions
In the Standard Consistency test described in §1.10, the percentage of water 'P' is definePer Table 1.5, the soundness of Ordinary Portland Cement tested by the Le Chatelier methodThe minimum specific surface (by Blaine air permeability) prescribed for Ordinary PortlandOil well cement, per the source, is engineered to remain mobile and then harden under apprAir entraining cement is used principally to improve the resistance of concrete to:Super sulphate cement is produced by inter-grinding granulated blast furnace slag with gypThe cement most ideally suited for mass concrete construction such as dams, per the sourceUnder the ASTM classification, the Type used when 'high sulphate resistance is required' i