The minimum wavelength $\lambda_{\min}$ in the continuous X-ray spectrum of an X-ray tube depends only on
Athe type of cathode
Bthe target material
Cthe accelerating voltage
Dthe filament current
Answer & Solution
Correct answer: C. the accelerating voltage
$\lambda_{\min} = \tfrac{hc}{eV}$, where $V$ is the accelerating voltage.
The cutoff is purely a kinematic limit set by how much energy a single electron can convert to a photon.
Target material affects the *characteristic* lines, not the continuous cutoff.
Keep practising Atoms and Nuclei
Browse all Atoms and Nuclei questions for AP Intermediate 2nd Year, or explore more Physics topics.
Related questions
The de Broglie wavelength $\lambda$ of an electron in the $n$th Bohr orbit of hydrogen, inNEET · Physics · Bohr's Atom — Gap FillThe radius of the $n$th Bohr orbit in a hydrogen-like atom of nuclear charge $Z$ scales asComplete Bohr's first postulateA radioactive sample has half-life $T_{1/2} = 5$ years. Starting with $N_0$ undecayed nuclThe ratio of the first excitation energy of a hydrogen atom ($E_2 - E_1$) to its ionisatioSpot the one that does not belongOrder the atomic models in this chapter