For a test core cut from a structure, the cube-equivalent strength is estimated as cube strength = 1.25 × C1 × C2 × core strength. The factor C2 depends on which property of the core?

Answer & Solution
Correct answer: A.
1. C1 accounts for core strength level and runs from 1.0 to 1.4. 2. C2 is specified in IS 516 and depends on the height-to-diameter ratio of the cut core. 3. When the L/D ratio of the core equals 2, C2 is taken as 1. 4. If the L/D ratio is less than 0.95 the core has to be discarded entirely. 5. Age, cement content and relative diameter are not what C2 corrects for. _Source: IGNOU ET-522 Concrete Technology, Block 2 Unit 9 "Testing of Concrete"._