Home › B.Tech Civil › civilengineering › Strength of Concrete › Per §7.2, the presence of 5 percent entrapped ai…
Per §7.2, the presence of 5 percent entrapped air voids in concrete can typically reduce its compressive strength by approximately:
A{'text': 'About 1 percent of the void-free value', 'label': 'A'}
B{'text': 'About 5 percent of the void-free value', 'label': 'B'}
C{'text': 'About 35 percent of the void-free value', 'label': 'C'}
D{'text': 'Effectively zero', 'label': 'D'}
Answer & Solution
Correct answer: C. {'text': 'About 35 percent of the void-free value', 'label': 'C'}
1. §7.2 states: 'The presence of these entrapped air voids in concrete greatly reduces its strength: 5 percent of voids can lower strength by as much as 35 percent and even 2 percent voids can result in a drop of strength of more than 10 percent.'
2. Hence even modest compaction defects severely hurt strength.
_Source: IGNOU ET-522 Block-2 Unit-7 Strength of Concrete, §7.2, p. 42_
Related questions
Per §7.6.4, the three types of shrinkage recognised in hardened-concrete deformation are:Per §7.6.3, the physical mechanism most often cited for creep deformation in concrete is:Per §7.6.3, if the creep deformation at 1 year is taken as unity, the source quotes the rePer §7.6.3, creep of concrete is best defined as the:Per §7.6.2, the modulus of elasticity of concrete typically scales approximately as which Per §7.6.1, the dynamic modulus of elasticity of concrete determined by ultrasonic-pulse /Per §7.6.1, for practical design, concrete may reasonably be treated as a linear-elastic mPer §7.6.1, in the standard determination of the Modulus of Elasticity the cylindrical con